{"id":171513,"date":"2025-03-07T06:48:55","date_gmt":"2025-03-07T06:48:55","guid":{"rendered":"https:\/\/www.maryatech.com\/?post_type=product&#038;p=171513"},"modified":"2026-03-11T14:52:44","modified_gmt":"2026-03-11T14:52:44","slug":"aislador-esteril","status":"publish","type":"product","link":"https:\/\/www.maryatech.com\/es\/product\/sterile-isolator\/","title":{"rendered":"Aislador est\u00e9ril"},"content":{"rendered":"<h2>Prestaciones y caracter\u00edsticas<\/h2>\n<ol>\n<li><strong><b>Nueva tecnolog\u00eda VHPS:<\/b><\/strong>controlan la concentraci\u00f3n y la saturaci\u00f3n de H<sub>2<\/sub>O<sub>2<\/sub>; buena reproducibilidad de la esterilizaci\u00f3n; acorta el tiempo de esterilizaci\u00f3n de la c\u00e1mara;<\/li>\n<li><strong><b>Dise\u00f1o modular:<\/b><\/strong>Incluye c\u00e1mara de transferencia, c\u00e1mara de operaci\u00f3n, colector de bacterias y otros m\u00f3dulos y configuraciones funcionales; f\u00e1cil de instalar y transportar;<\/li>\n<li><strong><b>Sistema de control inteligente:<\/b><\/strong>Sistema de control Siemens PLC+IPC; alarmas inteligentes de presi\u00f3n, H<sub>2<\/sub>O<sub>2<\/sub>\u00a0concentraci\u00f3n de la soluci\u00f3n, temperatura y humedad, velocidad del aire y otros par\u00e1metros de monitorizaci\u00f3n; el sistema dispone de control de acceso multinivel; cumple los requisitos de la FDA 21 CFR parte 11;<\/li>\n<li><strong><b>Servicio CDCV:<\/b><\/strong>desarrollo de ciclos de esterilizaci\u00f3n, estudios de validaci\u00f3n y servicios;<\/li>\n<li><strong><b>Detector inal\u00e1mbrico de fugas en guantes:<\/b><\/strong>El detector de fugas de guantes integrado o inal\u00e1mbrico es opcional;<\/li>\n<li><strong><b>Ahorro de energ\u00eda y reducci\u00f3n del consumo:<\/b><\/strong>dise\u00f1o optimizado del sistema de tratamiento del flujo de aire; el consumo de energ\u00eda de un funcionamiento continuo de ocho horas se reduce en 20%;<\/li>\n<li><strong><b>Supervisi\u00f3n en tiempo real del estado de la puerta: <\/b><\/strong>puede supervisar la apertura de la puerta en l\u00ednea y controlar continuamente la estanqueidad de la puerta;<\/li>\n<li><strong><b>Materiales de fabricaci\u00f3n de alta calidad: <\/b><\/strong>la c\u00e1mara interior est\u00e1 hecha de 316L o PTFE, y el grado de pulido de la c\u00e1mara es de 0,4\u03bcm~0,6\u03bcm;<\/li>\n<li><strong><b>Filtro de descomposici\u00f3n:<\/b><\/strong>el m\u00f3dulo de escape de aire puede estar equipado con un filtro de descomposici\u00f3n puede acortar eficazmente el tiempo de degradaci\u00f3n despu\u00e9s de H<sub>2<\/sub>O<sub>2<\/sub>\u00a0esterilizaci\u00f3n, y reducir eficazmente el nivel de concentraci\u00f3n de residuos;<\/li>\n<li><strong><b>Mantenimiento sencillo: <\/b><\/strong>la superficie de mantenimiento est\u00e1 en la parte delantera, y el espacio necesario para el laboratorio no es grande.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Como equipo de descontaminaci\u00f3n que separa a los operarios de las m\u00e1quinas y cumple los requisitos del entorno de clase A, el aislador est\u00e9ril se utiliza principalmente para la protecci\u00f3n de pruebas est\u00e9riles, dispensaci\u00f3n de productos est\u00e9riles y otros procesos clave. Puede reducir los requisitos de fondo o de entorno, mejorar la fiabilidad de los resultados de inspecci\u00f3n, cumplir los requisitos de GMP y Farmacopea de China, GMP\/FDA de la UE y cGMP\/USP-NF, y puede llevar a cabo un funcionamiento \u201ccontinuo\u201d o \u201cpor lotes\u201d.<\/p>","protected":false},"featured_media":290915,"template":"","meta":{"om_disable_all_campaigns":false,"_templately_pack_id":"","_templately_imported_at":"","_templately_source":"","_templately_import_session_id":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[115,118],"product_tag":[],"class_list":["post-171513","product","type-product","status-publish","has-post-thumbnail","product_cat-isolator-system","product_cat-sterile-isolator","desktop-align-left","tablet-align-left","mobile-align-left","first","instock","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.8 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Sterile Isolator -<\/title>\n<meta name=\"description\" content=\"As a decontamination equipment separating operators and machines and complying with the requirements of Class A environment, the sterile isolator is mainly used for the protection of sterile testing, sterile product dispensing and other key process.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.maryatech.com\/es\/producto\/aislador-esteril\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sterile Isolator\" \/>\n<meta property=\"og:description\" content=\"High-end sterile pharmaceutical filling lines manufacturer, with core strengths in complying with EU GMP\/FDA certification, serving multinational pharmaceutical companies.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.maryatech.com\/es\/producto\/aislador-esteril\/\" \/>\n<meta property=\"og:site_name\" content=\"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-11T14:52:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.maryatech.com\/wp-content\/uploads\/2025\/03\/Sterile-Isolator22.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@Shanghai_Marya\" \/>\n<meta name=\"twitter:label1\" content=\"Precio\" \/>\n\t<meta name=\"twitter:data1\" content=\"\" \/>\n\t<meta name=\"twitter:label2\" content=\"Disponibilidad\" \/>\n\t<meta name=\"twitter:data2\" content=\"Disponible\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/\",\"url\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/\",\"name\":\"Sterile Isolator -\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.maryatech.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/Sterile-Isolator22.jpg\",\"datePublished\":\"2025-03-07T06:48:55+00:00\",\"dateModified\":\"2026-03-11T14:52:44+00:00\",\"description\":\"As a decontamination equipment separating operators and machines and complying with the requirements of Class A environment, the sterile isolator is mainly used for the protection of sterile testing, sterile product dispensing and other key process.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.maryatech.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/Sterile-Isolator22.jpg\",\"contentUrl\":\"https:\\\/\\\/www.maryatech.com\\\/wp-content\\\/uploads\\\/2025\\\/03\\\/Sterile-Isolator22.jpg\",\"width\":800,\"height\":800,\"caption\":\"Sterile Isolator\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.maryatech.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mahsulotlar\",\"item\":\"https:\\\/\\\/www.maryatech.com\\\/uz\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Sterile Isolator\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/#website\",\"url\":\"https:\\\/\\\/www.maryatech.com\\\/\",\"name\":\"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.\",\"description\":\"Professional Aseptic Filling Line Manufacturer \u00b7 Turnkey Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/#organization\"},\"alternateName\":\"Shanghai Marya\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.maryatech.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":[\"Organization\",\"Place\"],\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/#organization\",\"name\":\"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.\",\"alternateName\":\"Marya\",\"url\":\"https:\\\/\\\/www.maryatech.com\\\/\",\"logo\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#local-main-organization-logo\"},\"image\":{\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#local-main-organization-logo\"},\"sameAs\":[\"https:\\\/\\\/x.com\\\/Shanghai_Marya\",\"https:\\\/\\\/www.youtube.com\\\/c\\\/ShanghaiMarya\\\/featured\",\"https:\\\/\\\/www.instagram.com\\\/maryapharma\\\/\"],\"telephone\":[\"19198185202\"],\"contactPoint\":{\"@type\":\"ContactPoint\",\"telephone\":\"19198185202\",\"email\":\"andy@maryatech.com\"},\"openingHoursSpecification\":[{\"@type\":\"OpeningHoursSpecification\",\"dayOfWeek\":[\"Monday\",\"Tuesday\",\"Wednesday\",\"Thursday\",\"Friday\",\"Saturday\",\"Sunday\"],\"opens\":\"09:00\",\"closes\":\"17:00\"}],\"email\":\"jany@marya.com.cn\",\"faxNumber\":\"\u4e0a\u6d77\u739b\u8859\u5236\u836f\u8bbe\u5907\u6709\u9650\u516c\u53f8\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.maryatech.com\\\/product\\\/sterile-isolator\\\/#local-main-organization-logo\",\"url\":\"https:\\\/\\\/www.maryatech.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/cropped-Marya-2-scaled.png\",\"contentUrl\":\"https:\\\/\\\/www.maryatech.com\\\/wp-content\\\/uploads\\\/2022\\\/12\\\/cropped-Marya-2-scaled.png\",\"width\":2560,\"height\":854,\"caption\":\"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.\"}]}<\/script>\n<meta property=\"product:price:currency\" content=\"USD\" \/>\n<meta property=\"og:availability\" content=\"instock\" \/>\n<meta property=\"product:availability\" content=\"instock\" \/>\n<meta property=\"product:condition\" content=\"new\" \/>\n<meta name=\"geo.region\" content=\"China\" \/>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Aislador est\u00e9ril -","description":"Como equipo de descontaminaci\u00f3n que separa a los operarios de las m\u00e1quinas y cumple los requisitos del entorno de clase A, el aislador est\u00e9ril se utiliza principalmente para la protecci\u00f3n de pruebas est\u00e9riles, dispensaci\u00f3n de productos est\u00e9riles y otros procesos clave.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.maryatech.com\/es\/producto\/aislador-esteril\/","og_locale":"es_ES","og_type":"article","og_title":"Sterile Isolator","og_description":"High-end sterile pharmaceutical filling lines manufacturer, with core strengths in complying with EU GMP\/FDA certification, serving multinational pharmaceutical companies.","og_url":"https:\/\/www.maryatech.com\/es\/producto\/aislador-esteril\/","og_site_name":"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.","article_modified_time":"2026-03-11T14:52:44+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2025\/03\/Sterile-Isolator22.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@Shanghai_Marya","twitter_misc":{"Precio":"","Disponibilidad":"Disponible"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/","url":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/","name":"Aislador est\u00e9ril -","isPartOf":{"@id":"https:\/\/www.maryatech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#primaryimage"},"image":{"@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#primaryimage"},"thumbnailUrl":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2025\/03\/Sterile-Isolator22.jpg","datePublished":"2025-03-07T06:48:55+00:00","dateModified":"2026-03-11T14:52:44+00:00","description":"Como equipo de descontaminaci\u00f3n que separa a los operarios de las m\u00e1quinas y cumple los requisitos del entorno de clase A, el aislador est\u00e9ril se utiliza principalmente para la protecci\u00f3n de pruebas est\u00e9riles, dispensaci\u00f3n de productos est\u00e9riles y otros procesos clave.","breadcrumb":{"@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.maryatech.com\/product\/sterile-isolator\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#primaryimage","url":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2025\/03\/Sterile-Isolator22.jpg","contentUrl":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2025\/03\/Sterile-Isolator22.jpg","width":800,"height":800,"caption":"Sterile Isolator"},{"@type":"BreadcrumbList","@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.maryatech.com\/"},{"@type":"ListItem","position":2,"name":"Mahsulotlar","item":"https:\/\/www.maryatech.com\/uz\/shop\/"},{"@type":"ListItem","position":3,"name":"Sterile Isolator"}]},{"@type":"WebSite","@id":"https:\/\/www.maryatech.com\/#website","url":"https:\/\/www.maryatech.com\/","name":"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.","description":"Fabricante profesional de l\u00edneas de llenado as\u00e9ptico - Soluciones llave en mano","publisher":{"@id":"https:\/\/www.maryatech.com\/#organization"},"alternateName":"Shanghai Marya","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.maryatech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":["Organization","Place"],"@id":"https:\/\/www.maryatech.com\/#organization","name":"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd.","alternateName":"Marya","url":"https:\/\/www.maryatech.com\/","logo":{"@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#local-main-organization-logo"},"image":{"@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#local-main-organization-logo"},"sameAs":["https:\/\/x.com\/Shanghai_Marya","https:\/\/www.youtube.com\/c\/ShanghaiMarya\/featured","https:\/\/www.instagram.com\/maryapharma\/"],"telephone":["19198185202"],"contactPoint":{"@type":"ContactPoint","telephone":"19198185202","email":"andy@maryatech.com"},"openingHoursSpecification":[{"@type":"OpeningHoursSpecification","dayOfWeek":["Monday","Tuesday","Wednesday","Thursday","Friday","Saturday","Sunday"],"opens":"09:00","closes":"17:00"}],"email":"jany@marya.com.cn","faxNumber":"\u4e0a\u6d77\u739b\u8859\u5236\u836f\u8bbe\u5907\u6709\u9650\u516c\u53f8"},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.maryatech.com\/product\/sterile-isolator\/#local-main-organization-logo","url":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2022\/12\/cropped-Marya-2-scaled.png","contentUrl":"https:\/\/www.maryatech.com\/wp-content\/uploads\/2022\/12\/cropped-Marya-2-scaled.png","width":2560,"height":854,"caption":"Shanghai Marya Pharmaceutical Engineering &amp; Project Co., Ltd."}]},"product_price_currency":"USD","og_availability":"instock","product_availability":"instock","product_condition":"new","geo.region":"China"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/product\/171513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/media\/290915"}],"wp:attachment":[{"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/media?parent=171513"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/product_brand?post=171513"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/product_cat?post=171513"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.maryatech.com\/es\/wp-json\/wp\/v2\/product_tag?post=171513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}